Smart city fiber optic infrastructure
Urban surveillance and traffic monitoring fiber solutions

Ouagadougou Server Hosting – West African Sahel

Browse technical resources about fiber optic infrastructure for smart cities, surveillance, and IoT.

  • What is the ideal thickness for a network server rack

    What is the ideal thickness for a network server rack

    4") is an industry standard server rack depth, many IT techs prefer 1200mm (47. 2") racks for today's modern installations with high density cabling and power hardware. This allows for a wide variety of equipment sizes and densities. Standard rack widths typically. While server cabinet height and width are fairly standardized, depth can be far ranging depending on the equipment you will be mounting. Airflow, cable space, and power distribution units (PDUs) all come into consideration when determining how deep you should design your server rack. The global standard width is 19 inches, as defined by the EIA-310 standard, ensuring compatibility across brands and countries like Dominican Republic, Iraq, and Maldives. The 19 inch dimension includes the edges or. Rack height is measured in rack units (U) — 1U = 1. Common sizes: 42U, 48U, and compact options like 22U–27U.

    [PDF Version]
  • How high should the network server rack be mounted

    How high should the network server rack be mounted

    It is neither safe nor convenient to operate the equipment installed at over 7 feet high. A server rack is more than just a physical frame—it determines how well your rack servers, network switches, PDUs, and storage arrays can be organized, cooled, and maintained. Selecting the right rack size ensures not only compatibility with today's hardware but also room for future expansion. The. Common server rack sizes are 19‑inch width, heights like 42U or 48U, and depths from ~24″ to 48″. Most IT environments default to 42U, 19-inch width, and 1000–1200 mm depth unless space constraints or special equipment dictate. A “Rack Unit” (U) is a standard height measure for mounting equipment in a server rack. This article explains definition, planning, installation tips, and trends. What Is a Rack Unit (U / RU)? Ready to Optimize Your Server Rack Setup? Rack Units, or “U,” are the standard. Picking the right server rack cabinet size helps your equipment fit properly and stay cool.

    [PDF Version]
  • South African Single-Fiber Bidirectional QSFP28

    South African Single-Fiber Bidirectional QSFP28

    With our extensive selection of QSFP28 100G Bidirectional transceivers, we can now provide single fibre 100G connectivity for links extending up to 40 kilometres. This capability simplifies network design and reduces costs associated with additional cabling. Designed for service providers, data center operators, and access networks, our Bidi. The Netshield 100G Quad Small Form-Factor Pluggable (QSFP28) compatibles allow a customer to leverage a variety of high-density and low-power 100 Gigabit Ethernet connectivity options. The module has built-in digital diagnostic functions, including optical power monitoring.


  • East African optical cable directly connects to Tonga

    East African optical cable directly connects to Tonga

    Tonga Cable System is a system connecting with, where it connects to other international networks. It is 827 kilometres (514 mi) long and was activated in 2013. It has at Sopu, a suburb of in, and, Fiji. The project was funded by and the. An extension of the cable to and was commissioned in April 2018.


  • How to insert fiber optic patch cords into the server room

    How to insert fiber optic patch cords into the server room

    They should be guided into patch panels along vertical posts on both sides at the back of the server rack - either upward or downward as needed. It is essential when racks of servers are used, to maintain a strong and secure. Proper installation and regular maintenance of fiber optic patch cords play a crucial role in achieving optimized network performance, preventing signal errors, and extending service life. Proper handling, routing, cleaning, bend-radius management, and connector alignment ensure that the optical link meets design. In today's high-performance networks, fiber optic patch cables are the lifelines that ensure smooth data flow across switches, servers, and routers. A systematic approach to preparation, routing, and using the right components can streamline the process. Before installing fiber optic cables, it's.

    [PDF Version]
  • How to secure the terminal box to the server rack

    How to secure the terminal box to the server rack

    Cabinet-level security involves installing locking mechanisms and access controls directly onto server racks, protecting the hardware that houses critical data. This is especially crucial in shared facilities, where multiple clients' servers reside side-by-side. Looking to keep your server rack mount equipment safe, organized, and running smoothly? In this video, we'll walk you through 5 simple yet powerful ways to secure your servers, switches, routers, and more inside your rackmount cabinet! From proper rails and screws to cable manageme Looking to keep. Strategic layout: Cabinets and racks should be placed in secure areas with restricted access. Ideally, they should be located in dedicated telecommunications rooms or data centers. This controlled environment helps prevent unauthorized physical access. This SmartRack® security panel installs to your EIA-standard 19-inch rack cabinet or open frame rack to keep your connected equipment, cabling and accessories safe. Without proper rack-level access.

    [PDF Version]
  • Outdoor server rack corrosion resistance rating C4

    Outdoor server rack corrosion resistance rating C4

    C4 introduces serious corrosion risk. A bare steel panel exposed to C4 will show visible rust within months. Coatings require 2–3 layers: zinc-rich epoxy primer (100–150 µm), epoxy intermediate (100–150 µm), polyurethane topcoat. ISO 12944 helps engineers select a protective coating system by defining atmospheric corrosivity categories (C1 to C5 and CX) and linking the environment + durability target to coating system performance expectations. If your project spec says “C3/C4/C5,” it's essentially telling you how aggressive. Selecting the appropriate steel for use in a corrosive environment classified as C4 (according to ISO 9223) is crucial. This system is used across many manufacturing and construction industries to enable a common language of corrosion environments to which each industry can adapt their. The C4 classification system is part of the ISO 12944 standard, which offers comprehensive guidelines for assessing the corrosion protection needs of steel structures exposed to diverse atmospheric conditions. Like other classifications in this standard, C4 designates a specific level of.

    [PDF Version]
  • Smart AI Home Cloud Server

    Smart AI Home Cloud Server

    Build a dedicated home AI server that runs 24/7 — serving LLMs to every device on your network. Hardware picks, networking, storage, remote access, and multi-user setup for families, teams, and tinkerers. Last updated: March 3, 2026. All hardware recommendations tested and. Ayush Pande is a PC hardware and gaming writer. When he's not working on a new article, you can find him with his head stuck inside a PC or tinkering with a server operating system. Besides computing, his interests include spending hours in long RPGs, yelling at his friends in co-op games, and. Maker, meme-r, and unabashed geek, Joe has been writing about technology since starting his career in 2018 at KnowTechie. Networking. Local AI is making the home very natural to control @AllenPorter, @shulyaka, @tronikos, @IvanLH, @Joostlek! We were doing voice assistants before AI was cool. In 2023, we kicked off our Year of the Voice. The platform for smart home control brings an integration for language.

    [PDF Version]

More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +49 172 6389472
Address Musterstraße 12, 10115 Berlin, Germany

Send an Inquiry